Summary for Test 2026-06-23-35-1

Test performed: AASHTO T59-25

Project Information

Project IdentifiersProject ID: 1001117
DEA: 033G4304
EFIS: 0324000127
DIST-CO-RTE-PM03-ED-89-0.0/8.5
Award Date06/06/2025
Closeout DateNot set
Work DescriptionCOLD PLANE AC PVMT AND HMA (TYPE A) OVERLAY.
Location DescriptionEL DORADO COUNTY NEAR MEYERS FROM ALPINE COUNTY LINE TO POMO STREET
QA Service Level1 (Verified on 04/02/2025)

Sample Information

Sample Taken Date06/23/2026 Sample Unique Key35
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing06/26/2026
Sample typeQuality Assurance A brief description of the sampleTack oil
The quantity of what the sample constitutes1 Jug From where was the sample collectedJob Site
First name of sampler or witnessed byEddie Last name of sampler or witnessed byPaniagua
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTahoe Asphalt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form00000 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphaltic Emulsion Emulsion GradeCQS-1h
Lot NumberNot set Sub LotNot set
Dilution Percentage RateN/A

Test Details

DIME Sample ID: 2026-06-23-35
DIME Test ID: 2026-06-23-35-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-25: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Test Release Date: 2026-06-30

Test Results


How many beakers will be used to conduct the test?: 2
Input Type: Measured
Tester's full name: Raul Cardenas
Date of test: 06/29/2026
Beaker 1 Mass of beaker, rod, screen (if used), and residue: 183.1 g
Beaker 1 Tare mass of the beaker, rod, and screen (if used): 151.4 g
Beaker 2 Mass of beaker, rod, screen (if used), and residue: 181.2 g
Beaker 2 Tare mass of the beaker, rod, and screen (if used): 150.6 g
Beaker 1 Residue: 63.4 %
Beaker 2 Residue: 61.2 %
Percentage of residue: 62 %
General comments (publicly viewable) (Max 1000 characters): evap

Test was verified on 6/30/2026