Summary for Test 2026-05-18-68-3

Test performed: AASHTO T51-22

Project Information

Project IdentifiersProject ID: 1000501
DEA: 081J6104
EFIS: 0818000102
DIST-CO-RTE-PM08-RIV-215-40.5/42.7
Award Date11/05/2024
Closeout DateNot set
Work DescriptionINDIVIDUAL SLAB REPLACEMENT (RSC), RHMA, AND REPLACE BASE.
Location DescriptionRIVERSIDE COUNTY IN RIVERSIDE FROM 0.8 MILE SOUTH OF ROUTE 60/91 SEPARATION TO 0.4 MILE SOUTH OF MARTIN LUTHER KING BOULEVARD UNDERCROSSING
QA Service Level1 (Verified on 09/02/2024)

Sample Information

Sample Taken Date05/18/2026 Sample Unique Key68
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/19/2026
Sample typeVerification A brief description of the sampleAsphalt Binder Sample
The quantity of what the sample constitutes1can From where was the sample collectedSource
First name of sampler or witnessed byFrancisco Last name of sampler or witnessed byRUVALCABA
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRJ Noble Orange Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierLunday Thagard Company-World Oil - South Gate CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2026-05-18-68
DIME Test ID: 2026-05-18-68-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2026-07-14

Test Results


Is a normal test obtainable?: Yes
Number of replicates tested: Two
Input Type: Measured
Tester's full name: Hussaya Leelakitrungruang
Date of test: 06/26/2026
Ductility of test #1 (D1): 43 cm
Ductility of test #2 (D2): 52 cm
Ductility of sample: 48 cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/14/2026