Summary for Test 2026-06-02-37-2
Test performed: CTM 389-19Project Information
| Project Identifiers | Project ID: 1002270 DEA: 113A9294 EFIS: 1125000135 |
|---|---|
| DIST-CO-RTE-PM | 11---unknown |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 06/02/2026 | Sample Unique Key | 37 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/03/2026 |
| Sample type | Verification | A brief description of the sample | JMF |
| The quantity of what the sample constitutes | 12 boxes | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Mohammed | Last name of sampler or witnessed by | Masud |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Martin Marietta Lakeside | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 23418180T3 | |
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | Valero | |
| RAP content (%) | 0 | WMA Additives | No |
| Antistrip type |
Test Details
DIME Sample ID: 2026-06-02-37
DIME Test ID: 2026-06-02-37-2
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2026-06-30
Test Results
Specified number of passes at 12.7 mm: 25000
Specimen Preparation Method: PMLC
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 06/24/2026
Test Temperature: 122 F
Compaction Method: SGC Cylindrical Specimen
Air Void Content for specimen A-1: 7.0 %
Air Void Content for specimen A-2: 6.6 %
Air Void Content for specimen B-1: 7.0 %
Air Void Content for specimen B-2: 7.0 %
Stripping Inflection Point (Wheel A): 25000
Stripping Inflection Point (Wheel B): 25000
Maximum impression at 5000 passes (left wheel): 0.98 mm
Maximum impression at 5000 passes (right wheel): 1.96 mm
Average impression at 5000 passes (left/right avg): 1.47 mm
Maximum impression at 10000 passes (left wheel): 1.89 mm
Maximum impression at 10000 passes (right wheel): 3.89 mm
Average impression at 10000 passes (left/right avg): 2.89 mm
Maximum impression at 15000 passes (left wheel): 2.66 mm
Maximum impression at 15000 passes (right wheel): 5.79 mm
Average impression at 15000 passes (left/right avg): 4.22 mm
Maximum impression at 20000 passes (left wheel): 3.31 mm
Maximum impression at 20000 passes (right wheel): 7.8 mm
Average impression at 20000 passes (left/right avg): 5.56 mm
Maximum impression at 25000 passes (left wheel): 4.4 mm
Maximum impression at 25000 passes (right wheel): 9.64 mm
Average impression at 25000 passes (left/right avg): 7.02 mm
Raw Data: excel
General comments (publicly viewable) (Max 1000 characters): Complies Target < 12.7 mm Tested an Avg of 7.02 mm
Test was verified on 6/30/2026 ✔