Summary for Test 2026-06-01-74-5

Test performed: AASHTO T316-22

Project Information

Project IdentifiersProject ID: 1000637
DEA: 031H1404
EFIS: 0316000060
DIST-CO-RTE-PM03-BUT-99-R3.1/5.0
Award Date01/08/2025
Closeout DateNot set
Work DescriptionRHMA, HMA, LIGHTING SYSTEMS, CURB RAMPS, SIDEWALKS, AND DRIVEWAYS.
Location DescriptionBUTTE COUNTY IN AND NEAR GRIDLEY FROM HOLLIS LANE TO 0.2 MILE NORTH OF FORD AVENUE
QA Service Level1 (Verified on 11/06/2024)

Sample Information

Sample Taken Date06/01/2026 Sample Unique Key74
Date that the sample was received by the laboratory/organization performing the testing06/10/2026 Sample typeQuality Assurance
A brief description of the sample58-22 The quantity of what the sample constitutes1 can of 58-22
From where was the sample collectedSource First name of sampler or witnessed bybrad
Last name of sampler or witnessed bym Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameteichert hallwood
Transportation Laboratory (TL) Number955803 Inspector Lot Number from the Transportation Laboratory (TL) Form955803
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
Modified Lot number1
Sublot number1 Tank number
Time of sample HMA SupplierTeichert Hallwood
Certified Asphalt SupplierPacific Northwest Oil - Stockton CA MultigradeYes
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2026-06-01-74
DIME Test ID: 2026-06-01-74-5
Testing Lab: Atlas - Denver
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2026-06-24

Test Results


Is viscosity reading in cP/Pa-s?: cP
Input Type: Measured
Tester's full name: Erik Svensson
Date of test: 06/24/2026
Time of test: 00:00 HH:MM
Test Temperature: 135.0 C
Speed: 20 rpm
Spindle size: .463 in
Torque: 16.4 %
Viscosity reading #1 (A) : 409 cP
Viscosity reading #2 (B) : 409 cP
Viscosity reading #3 (C): 409 cP
Average viscosity : 0.409 Pa-s
General comments (publicly viewable) (Max 1000 characters): VISCOSITY @ 135C

Test was verified on 6/24/2026 ✔