Summary for Test 2026-06-15-54-2

Test performed: AASHTO T308-25

Project Information

Project IdentifiersProject ID: 1001609
DEA: 040AA244
EFIS: 0419000455
DIST-CO-RTE-PM04-CC, -680-R0.0/R7.7
Award Date12/18/2025
Closeout DateNot set
Work DescriptionINDIVIDUAL SLAB REPLACEMENT, COLD PLAN AC PVMT, GRIND EXIST CONC PVMT.
Location DescriptionCONTRA COSTA COUNTY IN SAN RAMON AND DANVILLE FROM THE ALAMEDA COUNTY LINE TO 0.2 MILE NORTH OF DIABLO ROAD UNDERCROSSING
QA Service Level1 (Verified on 10/06/2025)

Sample Information

Sample Taken Date06/15/2026 Sample Unique Key54
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/16/2026
Sample typeProduction Start-Up A brief description of the sample3/4"HMA w/25% RAP
The quantity of what the sample constitutes750 Tons From where was the sample collectedSource
First name of sampler or witnessed byDennis Last name of sampler or witnessed byYeung
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Pleasanton Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2026-06-15-54
DIME Test ID: 2026-06-15-54-2
Testing Lab: CT D04 - Pleasanton Field Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-06-22

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Dennis Yeung
Date of test: 06/22/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 3558.9 g
Mass of the specimen and specimen basket assembly prior to ignition: 5670.1 g
Mass of HMA Sample prior to ignition: 2111.2 g
Mass Loss: 132.1 g
Mass of aggregate remaining after ignition: 1979.1 g
Correction Factor (Percent by mass of HMA Specimen): 1.38 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.13 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 4.75 %
General comments (publicly viewable) (Max 1000 characters): PSUE Sample (Burn #2)

Test was verified on 6/22/2026