Summary for Test 2026-06-12-37-1

Test performed: AASHTO T308-25

Project Information

Project IdentifiersProject ID: 1001153
DEA: 081L3104
EFIS: 0820000020
DIST-CO-RTE-PM08-RIV-74-11.8/17.3
Award Date06/06/2025
Closeout DateNot set
Work DescriptionRHMA (GAP GRADED), REPLACE AC SURF, AND COLD PLANE AC PVMT.
Location DescriptionRIVERSIDE COUNTY IN LAKE ELSINORE FROM GRAND AVENUE TO ROUTE 15/74 SEPARATION
QA Service Level1 (Verified on 05/05/2025)

Sample Information

Sample Taken Date06/12/2026 Sample Unique Key37
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/15/2026
Sample typeAcceptance A brief description of the sample1/2" RWMA-G
The quantity of what the sample constitutes179.44 Tons From where was the sample collectedSource
First name of sampler or witnessed byJacob Last name of sampler or witnessed byGarcia
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRJ Nobel - Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2026-06-12-37
DIME Test ID: 2026-06-12-37-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-06-23

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Vincent Onoh
Date of test: 06/20/2026
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1590.0 g
Mass Loss: 134.9 g
Correction Factor (Percent by mass of HMA Specimen): 0.56 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.18 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 7.74 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/23/2026