Summary for Test 2026-06-05-43-1

Test performed: AASHTO T308-25

Project Information

Project IdentifiersProject ID: 1001098
DEA: 081P0804
EFIS: 0823000089
DIST-CO-RTE-PM08-RIV-10-7.0/44.5
Award Date06/03/2025
Closeout DateNot set
Work DescriptionFURNISH & PLACE POLYESTER CONCRETE OVERLAY, JOINT SEAL, HMA (BRIDGE).
Location DescriptionRIVERSIDE COUNTY AT VARIOUS LOCATIONS FROM VEILE AVENUE UNDERCROSSING IN BEAUMONT TO MONTEREY AVENUE OVERCROSSING AT THOUSAND PALMS
QA Service Level1 (Verified on 04/07/2025)

Sample Information

Sample Taken Date06/05/2026 Sample Unique Key43
Date that the sample was received by the laboratory/organization performing the testing06/12/2026 Sample typeAcceptance
A brief description of the sample1/2" HMA-A The quantity of what the sample constitutes4 BOXES, 37.50 TONS
From where was the sample collectedSupplier First name of sampler or witnessed byMM
Last name of sampler or witnessed byQC Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameMartin Marietta Coachella
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number41217195WM
Binder content (%)5.0 Virgin binder PG
Design binder PG PG 64-16 Binder SupplierVALERO
RAP content (%)25 WMA AdditivesNo
Antistrip type0.30% INGEVITY EVOTHEM

Test Details

DIME Sample ID: 2026-06-05-43
DIME Test ID: 2026-06-05-43-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-06-20

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Elias Hamel
Date of test: 06/18/2026
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1662.4 g
Mass Loss: 94.6 g
Correction Factor (Percent by mass of HMA Specimen): 0.41 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.18 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.10 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/20/2026 ✔