Summary for Test 2018-01-25-9-1
Test performed: ASTM C496-17Project Information
| Project Identifiers | Project ID: 208945 DEA: 07288604 EFIS: 0700021080 COOP: 074663 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-710-6.0-9.4 |
| Award Date | 09/02/2011 |
| Closeout Date | Not set |
| Work Description | Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing. |
| Location Description | Port of Long Beach (District 7) |
| QA Service Level | 1 (Verified on 06/03/2013) |
Sample Information
| Sample Taken Date | 01/25/2018 | Sample Unique Key | 9 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/12/2018 |
| Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylinders |
| The quantity of what the sample constitutes | 6x12 Cylinders | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Sherri | Last name of sampler or witnessed by | brannon |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | a a ready mix | Transportation Laboratory (TL) Number | c946376 L48-002-18 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | c946376 L48-002-18 | Structure unique identifier | Unknown |
| Structure name | Unknown | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | SFI-LWSBS5 |
|---|---|---|---|
| The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | 5800143 |
| Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| A detailed description of where the material sample was collected | Unknown | Where the material sample would have been placed if not sampled | Unknown |
| From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2018-01-25-9
DIME Test ID: 2018-01-25-9-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C496-17: Standard Test Method for Splitting Tensile Strength of Cylindrical Concrete Specimens (Split Tensile Strength)
Test Release Date: 2018-03-22
Test Results
Number of Specimens: 2
Input Type: Measured
Tester's full name: Bang Nguyen
Date of test: 03/22/2018
Diameter (specimen 1): 6.02 in
Diameter (specimen 2): 6.03 in
Length (specimen 1): 11.94 in
Length (specimen 2): 11.94 in
Maximum applied load indicated by the testing machine (specimen 1): 55110 lbf
Maximum applied load indicated by the testing machine (specimen 2): 51490 lbf
Age (specimen 1): 56 days
Age (specimen 2): 56 days
Split Tensile Strength (specimen 1): 490 psi
Split Tensile Strength (specimen 2): 455 psi
Average Split Tensile Strength: 475 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/13/2018 ✔