Summary for Test 2026-04-27-14-1

Test performed: CONCLP 4-16

Project Information

Project IdentifiersProject ID: 1002116
DEA: 081N2104
EFIS: 0822000119
DIST-CO-RTE-PM08-SBD-10-26.2/R37.0
Award Date01/07/2026
Closeout DateNot set
Work DescriptionStructural concrete, furnish and place polyester concrete overlay.
Location DescriptionCONSTRUCTION ON STATE HIGHWAY IN SAN BERNARDINO COUNTY AT VARIOUS LOCATIONS FROM TIPPECANOE AVENUE IN LOMA LINDA TO LIVE OAK CANYON ROAD IN YUCAIPA
QA Service Level1 (Verified on 05/04/2026)

Sample Information

Sample Taken Date04/27/2026 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/27/2026
Sample typeQuality Control A brief description of the sample2 pints KBP 204, CHP, 8020
The quantity of what the sample constitutes100 Totes From where was the sample collectedSource
First name of sampler or witnessed byGILBERTO Last name of sampler or witnessed byGONZALEZ
Title of samplerQAULITY CONTROL MANAGER Telephone number of sampler925-913-9199
Laboratory sample identification26-017 Linked DIME Sample ID
The fabricator/manufacturer/facility nameKwik Bond Polymers, Benicia Transportation Laboratory (TL) Number213KBP
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeMethacrylate Mfg. Lot Number(s)2660651750
Batch Number26-60-651750 Mix number2660651750

Test Details

DIME Sample ID: 2026-04-27-14
DIME Test ID: 2026-04-27-14-1
Testing Lab: Future Labs, LLC
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2026-06-17

Test Results


Input Type: Calculated
Tester's full name: Alex Hamilton
Date of test: 06/17/2026
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 20 cps
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 9.1
Volatile content (ASTM D 2369) 30% max: 3.5 %
Flash point (ASTM D 3828) more than 180 deg F: 212 F
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: 633 psi
Tack free time, 400 minutes max: 351 minutes
General comments (publicly viewable) (Max 1000 characters): PCC-SSD bond strength(CT 551) and tack free time accepted based on supplier's results.

Test was verified on 6/17/2026