Summary for Test 2026-04-27-14-1
Test performed: CONCLP 4-16Project Information
| Project Identifiers | Project ID: 1002116 DEA: 081N2104 EFIS: 0822000119 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-10-26.2/R37.0 |
| Award Date | 01/07/2026 |
| Closeout Date | Not set |
| Work Description | Structural concrete, furnish and place polyester concrete overlay. |
| Location Description | CONSTRUCTION ON STATE HIGHWAY IN SAN BERNARDINO COUNTY AT VARIOUS LOCATIONS FROM TIPPECANOE AVENUE IN LOMA LINDA TO LIVE OAK CANYON ROAD IN YUCAIPA |
| QA Service Level | 1 (Verified on 05/04/2026) |
Sample Information
| Sample Taken Date | 04/27/2026 | Sample Unique Key | 14 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/27/2026 |
| Sample type | Quality Control | A brief description of the sample | 2 pints KBP 204, CHP, 8020 |
| The quantity of what the sample constitutes | 100 Totes | From where was the sample collected | Source |
| First name of sampler or witnessed by | GILBERTO | Last name of sampler or witnessed by | GONZALEZ |
| Title of sampler | QAULITY CONTROL MANAGER | Telephone number of sampler | 925-913-9199 |
| Laboratory sample identification | 26-017 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Kwik Bond Polymers, Benicia | Transportation Laboratory (TL) Number | 213KBP |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Methacrylate | Mfg. Lot Number(s) | 2660651750 |
|---|---|---|---|
| Batch Number | 26-60-651750 | Mix number | 2660651750 |
Test Details
DIME Sample ID: 2026-04-27-14
DIME Test ID: 2026-04-27-14-1
Testing Lab: Future Labs, LLC
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2026-06-17
Test Results
Input Type: Calculated
Tester's full name: Alex Hamilton
Date of test: 06/17/2026
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 20 cps
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 9.1
Volatile content (ASTM D 2369) 30% max: 3.5 %
Flash point (ASTM D 3828) more than 180 deg F: 212 F
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: 633 psi
Tack free time, 400 minutes max: 351 minutes
General comments (publicly viewable) (Max 1000 characters): PCC-SSD bond strength(CT 551) and tack free time accepted based on supplier's results.
Test was verified on 6/17/2026 ✔