Summary for Test 2026-06-04-139-1

Test performed: AASHTO T308-25

Project Information

Project IdentifiersProject ID: 1002108
DEA: 081T3104
EFIS: 0826000039
DIST-CO-RTE-PM08-RIV-74-74.5/92.1
Award Date11/17/2025
Closeout DateNot set
Work DescriptionRepair fire damaged roadway, guardrails, signs and existing drainage systems
Location DescriptionIn Riverside County in Santa Rosa and San Jacinto Mountains National Monument from on State Route 74(SR 74) from Postmile 74.5 to Postmile 92.1
QA Service Level1 (Verified on 04/29/2026)

Sample Information

Sample Taken Date06/04/2026 Sample Unique Key139
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/11/2026
Sample typeAcceptance A brief description of the sample3/4" HMA-A
The quantity of what the sample constitutes2 BOXES, 200 TONS From where was the sample collectedSupplier
First name of sampler or witnessed byABBAS Last name of sampler or witnessed byKHANSAR
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Desert Hot Springs Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number7 HMA Mix Number1466
Binder content (%)4.5 Virgin binder PG PG 70-10
Design binder PG PG 70-10 Binder SupplierVALERO
RAP content (%)25 WMA AdditivesNo
Antistrip type0.50% INGEVITY EVOTHERM

Test Details

DIME Sample ID: 2026-06-04-139
DIME Test ID: 2026-06-04-139-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-06-18

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Elias Hamel
Date of test: 06/16/2026
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2170.1 g
Mass Loss: 98.7 g
Correction Factor (Percent by mass of HMA Specimen): 0.03 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.38 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/18/2026