Summary for Test 2026-05-19-69-3

Test performed: ASTM D624-00r20

Project Information

Project IdentifiersProject ID: 1001152
DEA: 07346104
EFIS: 0718000071
DIST-CO-RTE-PM07-LA-1-7.0/7.4
Award Date07/15/2025
Closeout DateNot set
Work DescriptionRETROFIT BRIDGE, REPLACE BRIDGE RAILINGS, AND CURB RAMPS.
Location DescriptionLOS ANGELES COUNTY IN LONG BEACH FROM GOLDEN AVENUE TO HARBOR AVENUE
QA Service Level1 (Verified on 08/11/2025)

Sample Information

Sample Taken Date05/19/2026 Sample Unique Key69
Date that the sample was received by the laboratory/organization performing the testing06/02/2026 Sample typeQuality Assurance
A brief description of the sampleBearing Pad The quantity of what the sample constitutes85
From where was the sample collectedManufacturer First name of sampler or witnessed byKrishnamoorthy
Last name of sampler or witnessed byPalaniappan Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameBridge Rubber Bearing
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM1 - Elastomeric Bearing Pad Mfg. Lot Number(s)2527-4
Material/Compound/Elastomer IDNA Samples Representing85
Description (size)1" x 4" x 6" Comments
Description (Number of Shims)0 Type of Bearing PadPlain
Description (Thickness of Shims)NA Manufacturer(s)Bridge Rubber Bearing
Batch Number155833

Test Details

DIME Sample ID: 2026-05-19-69
DIME Test ID: 2026-05-19-69-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D624-00r20: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Test Release Date: 2026-06-16

Test Results


Number of specimens tested: 3
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 06/16/2026
Humidity: 0 %
Temperature: 0 f
Sample 1 Median Thickness: 0.073 in
Sample 1 Tear Strength: 206 lb/in
Sample 2 Median Thickness: 0.088 in
Sample 2 Tear Strength: 207 lb/in
Sample 3 Median Thickness: 0.083 in
Sample 3 Tear Strength: 192 lb/in
UTM: NA
Median of the Tear Strength Values: 206 lb/in
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/16/2026 ✔