Summary for Test 2026-06-02-59-7

Test performed: AASHTO T335-09r13

Project Information

Project IdentifiersProject ID: 1000785
DEA: 081J3204
EFIS: 0818000017
DIST-CO-RTE-PM08-RIV-74-17.8
Award Date05/29/2025
Closeout DateNot set
Work DescriptionBUILDING WORK, WROUGHT IRON FENCE, HOT MIX ASPHALT, & AGGREGATE BASE.
Location DescriptionRIVERSIDE COUNTY NEAR LAKE ELSINORE AT LAKE ELSINORE MAINTENANCE STATION AT 18745 CONARD AVENUE
QA Service Level1 (Verified on 01/13/2025)

Sample Information

Sample Taken Date06/02/2026 Sample Unique Key59
Date that the sample was received by the laboratory/organization performing the testing06/05/2026 Sample typeVerification
A brief description of the samplePSU, 3/4" HMA-A-SP R15 No LAS The quantity of what the sample constitutes2 Bags of Combined, 2 Bags of RAP
From where was the sample collectedManufacturer First name of sampler or witnessed byDylan
Last name of sampler or witnessed byNault Title of samplerMREAS
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameAll American Asphalt Corona
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0005
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut at Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number105793 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2026-06-02-59
DIME Test ID: 2026-06-02-59-7
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)
Test Release Date: 2026-06-24

Test Results


Method: 1 - Combined Fracture Determination
Aggregate Size and Fracture Type: Coarse 1 and 2 Faced and Fine 1 Faced
Input Type: Calculated
Tester's full name: DP
Date of test: 06/12/2026
Percentage of fractured, coarse, 2 faced particles tested: 100 %
Percentage of fractured, coarse, 1 faced particles tested: 100 %
Percentage of fractured, fine, 1 faced particles tested: 100 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/24/2026 ✔