Summary for Test 2026-06-09-24-1
Test performed: AASHTO T308-25Project Information
| Project Identifiers | Project ID: 1001723 DEA: 050N7064 EFIS: 0524000077 |
|---|---|
| DIST-CO-RTE-PM | 05-SB-101-10.9/12.3 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | SB 101 - Segment 4E North - Cabrillo |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 11/03/2025) |
Sample Information
| Sample Taken Date | 06/09/2026 | Sample Unique Key | 24 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/09/2026 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4 HMA SP R25 |
| The quantity of what the sample constitutes | 0-750 Tons | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Jesse | Last name of sampler or witnessed by | Gomez |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Granite Santa Paula | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 10 | HMA Mix Number | 14851 |
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-06-09-24
DIME Test ID: 2026-06-09-24-1
Testing Lab: CT D05 - Carpinteria Field Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-06-15
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Jesse Gomez
Date of test: 06/10/2026
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2061.0 g
Mass Loss: 106.3 g
Correction Factor (Percent by mass of HMA Specimen): 0.50 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 4.66 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/15/2026 ✔