Summary for Test 2026-06-07-3-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1001573 DEA: 060X2904 EFIS: 0618000050 |
|---|---|
| DIST-CO-RTE-PM | 06-FRE-33-13.9/16.7 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | HMA (TYPE A), RDWY EXC, CL 2 AB, CURB RAMPS AND MOBILIZATION. |
| Location Description | FRESNO COUNTY IN AND NEAR COALINGA FROM ENTERPRISE PARKWAY TO LOS GATOS CREEK SOUTH CHANNEL BRIDGE |
| QA Service Level | 1 (Verified on 09/15/2025) |
Sample Information
| Sample Taken Date | 06/07/2026 | Sample Unique Key | 3 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/07/2026 | Sample type | Acceptance |
| A brief description of the sample | 3/4 HMA pg 64-16 | The quantity of what the sample constitutes | 1875 tons |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Jonathon |
| Last name of sampler or witnessed by | Chaney | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Granite Construction Company | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-06-07-3
DIME Test ID: 2026-06-07-3-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-06-15
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 06/08/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 2925.7 g
Mass of the specimen and specimen basket assembly prior to ignition: 5203.4 g
Mass of HMA Sample prior to ignition: 2277.7 g
Mass Loss: 144.0 g
Mass of aggregate remaining after ignition: 2133.7 g
Correction Factor (Percent by mass of HMA Specimen): 1.25 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.13 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 4.94 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/15/2026 ✔