Summary for Test 2025-08-18-123-5

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 1001391
DEA: 051S4904
EFIS: 0525000044
DIST-CO-RTE-PM05-SB-1-10.14
Award DateNot set
Closeout DateNot set
Work DescriptionExcavating and Grading, repair/stabilize embankment, Soldier Pile Wall construction, Paving, Providing temporary traffic control
Location DescriptionNot set
QA Service Level1 (Verified on 07/15/2025)

Sample Information

Sample Taken Date08/18/2025 Sample Unique Key123
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/19/2025
Sample typeQuality Control A brief description of the sample4x8 Cylinders
The quantity of what the sample constitutes8 From where was the sample collectedJob Site
First name of sampler or witnessed byBrenda Last name of sampler or witnessed byAmaya
Title of samplerField Technician Telephone number of sampler
Laboratory sample identification710GN1010 Set 1 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCalPortland Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameCIDH Pile 12 Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number710GN1010
The truck number from where the sample was collectedLoad 1 The batch plant ticket number from where the sample was collected0
Concrete batch plantCalPortland The fabricator/manufacturer designation for the sampleSet 1
A detailed description of where the material sample was collectedCIDH Pile 12 Where the material sample would have been placed if not sampled
From Lot No.1 Bag Lot No.1

Test Details

DIME Sample ID: 2025-08-18-123
DIME Test ID: 2025-08-18-123-5
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2026-06-19

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Michael Kaus
Date of test: 09/15/2025
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 55110 lb
Maximum load on cylinder 2: 52300 lb
Maximum load on cylinder 3: 56040 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength (to nearest 10 psi): 4340 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/19/2026