Summary for Test 2026-06-04-132-1

Test performed: AASHTO T308-25

Project Information

Project IdentifiersProject ID: 1001960
DEA: 081J65U4
EFIS: 0824000091
DIST-CO-RTE-PM08-RIV-10-0.0/R8.2
Award DateNot set
Closeout DateNot set
Work DescriptionHMA, RHMA, JPCP, JPCP(RSC), and individual slab replacement (RSC).
Location DescriptionNot set
QA Service Level1 (Verified on 03/23/2026)

Sample Information

Sample Taken Date06/04/2026 Sample Unique Key132
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/09/2026
Sample typeAcceptance A brief description of the sample3/4" HMA-A
The quantity of what the sample constitutes2 BOXES, 155.40 TONS From where was the sample collectedSupplier
First name of sampler or witnessed byIDRIS Last name of sampler or witnessed byNAJJAR
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameALL AMERICAN ASPHALT-CORONA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number105793
Binder content (%)4.7 Virgin binder PG
Design binder PG Binder SupplierSJR
RAP content (%)15 WMA AdditivesNo
Antistrip typeNONE

Test Details

DIME Sample ID: 2026-06-04-132
DIME Test ID: 2026-06-04-132-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-06-15

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Elias Hamel
Date of test: 06/12/2026
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2173.4 g
Mass Loss: 110.5 g
Correction Factor (Percent by mass of HMA Specimen): 0.36 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.59 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/15/2026