Summary for Test 2018-04-02-5-1
Test performed: AASHTO T27-14Project Information
| Project Identifiers | Project ID: 212886 DEA: 023H1204 |
|---|---|
| DIST-CO-RTE-PM | 02-TEH-5-R0.0/R22.4 |
| Award Date | 01/03/2018 |
| Closeout Date | 02/06/2019 |
| Work Description | COLD PLANE RAC-O, PLACE RHMA-O, REPLACE AC SURFACING, MBGR |
| Location Description | TEHAMA COUNTY AT AND NEAR CORNING FROM GLENN COUNTY LINE TO 0.3 MILE NORTH OF BRANCH COYOTE CREEK BRIDGE |
| QA Service Level | 1 (Verified on 01/08/2019) |
Sample Information
| Sample Taken Date | 04/02/2018 | Sample Unique Key | 5 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/03/2018 |
| Sample type | Department Acceptance | A brief description of the sample | Combined 3/4-inch Type A Aggregate |
| The quantity of what the sample constitutes | Production Start Up Evaluation | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Michael | Last name of sampler or witnessed by | Allegretto |
| Title of sampler | Lab Tech | Telephone number of sampler | Unknown |
| Laboratory sample identification | 17-07-P07, D77311F | Linked DIME Sample ID | 2018-04-02-3,4 |
| The fabricator/manufacturer/facility name | Tullis Inc - Northstate Asphalt - Redding, CA | Transportation Laboratory (TL) Number | 852090 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-45-0057 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| The plant number | Unknown | A detailed description of where the material sample was collected | Mathmatically Combined |
| Where the material sample would have been placed if not sampled | Digout HMA | Primary Aggregate Nominal Size | 3/4 inch |
| The concrete mix design number | Unknown | Lot number | Not set |
| Sublot number | Not set | Aggregate Mix Number | Not set |
| HMA Pay | No |
Test Details
DIME Sample ID: 2018-04-02-5
DIME Test ID: 2018-04-02-5-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2018-04-06
Test Results
What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Ward Jenkins
Date of test: 04/06/2018
| Cumulative Percent Passing | ||||||
|---|---|---|---|---|---|---|
| % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 90 % | ||||||
| 68 % | ||||||
| 49 % | ||||||
| 43 % | ||||||
| 28 % | ||||||
| 19 % | ||||||
| 13 % | ||||||
| 9 % | ||||||
| 7 % | ||||||
| 4.9 % | ||||||
General comments (publicly viewable) (Max 1000 characters): 1/4-inch sieve value is approximate.
Test was verified on 4/6/2018 ✔