Summary for Test 2018-04-02-4-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 212886
DEA: 023H1204
DIST-CO-RTE-PM02-TEH-5-R0.0/R22.4
Award Date01/03/2018
Closeout Date02/06/2019
Work DescriptionCOLD PLANE RAC-O, PLACE RHMA-O, REPLACE AC SURFACING, MBGR
Location DescriptionTEHAMA COUNTY AT AND NEAR CORNING FROM GLENN COUNTY LINE TO 0.3 MILE NORTH OF BRANCH COYOTE CREEK BRIDGE
QA Service Level1 (Verified on 01/08/2019)

Sample Information

Sample Taken Date04/02/2018 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing04/03/2018 Sample typeDepartment Acceptance
A brief description of the sampleCombined RAP The quantity of what the sample constitutesProduction Start Up Evaluation
From where was the sample collectedManufacturer First name of sampler or witnessed byMichael
Last name of sampler or witnessed byAllegretto Title of samplerLab Tech
Telephone number of samplerUnknown Laboratory sample identification17-07-P07, D77311B
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameTullis Inc - Northstate Asphalt - Redding, CA
Transportation Laboratory (TL) Number852090 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceNorthstate Asphalt
Aggregate SizeCombined Aggregate SourceUnknown
RAP StockpileStatic Stockpile Size (tons)Unknown
Reclaimed Asphalt Pavement Mix NumberNot set HMA PayNo

Test Details

DIME Sample ID: 2018-04-02-4
DIME Test ID: 2018-04-02-4-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2018-04-06

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Colt Sweeny
Date of test: 04/04/2018
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): no data
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 6.22 %
General comments (publicly viewable) (Max 1000 characters): 5.33 est. Pbr

Test was verified on 4/6/2018 ✔