Summary for Test 2026-06-11-6-3
Test performed: AASHTO T308-25Project Information
| Project Identifiers | Project ID: 1002310 DEA: 010P6404 EFIS: 0125000053 |
|---|---|
| DIST-CO-RTE-PM | 01-HUM-101-R131.7/134.6 |
| Award Date | 02/17/2026 |
| Closeout Date | Not set |
| Work Description | Boyes Creek Viaduct |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 06/11/2026 | Sample Unique Key | 6 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/11/2026 |
| Sample type | Quality Assurance | A brief description of the sample | 1/2 RHMA PG 64-16 |
| The quantity of what the sample constitutes | 4 boxs | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Jacob | Last name of sampler or witnessed by | Knipscheer |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Mercer Fraser Boyd Road | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-06-11-6
DIME Test ID: 2026-06-11-6-3
Testing Lab: CT D01 - Boyd Road Field Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-06-11
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: jacob Knipscheer-costello
Date of test: 06/11/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 3923.1 g
Mass of the specimen and specimen basket assembly prior to ignition: 5499.0 g
Mass of HMA Sample prior to ignition: 1575.9 g
Mass Loss: 144.6 g
Mass of aggregate remaining after ignition: 1431.3 g
Correction Factor (Percent by mass of HMA Specimen): 0.95 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 8.23 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/11/2026 ✔