Summary for Test 2026-04-16-78-4

Test performed: ASTM C78-18

Project Information

Project IdentifiersProject ID: 1000259
DEA: 050N74V4
EFIS: 0522000043
DIST-CO-RTE-PM05-SB-101-9.2/9.7
Award Date02/08/2024
Closeout DateNot set
Work DescriptionNot set
Location DescriptionFOR CONSTRUCTION ON STATE HIGHWAY IN SANTA BARBARA COUNTY AT MONTECITO FROM 0.2 MILE NORTH OF SHEFFIELD DRIVE UNDERCROSSING TO 0.3 MILE SOUTH OF SAN YSIDRO ROAD OVERCROSSING
QA Service Level1 (Verified on 04/15/2024)

Sample Information

Sample Taken Date04/16/2026 Sample Unique Key78
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/16/2026
Sample typeQuality Assurance A brief description of the sampleCRCP Concrete Sample
The quantity of what the sample constitutes600 CY From where was the sample collectedManufacturer
First name of sampler or witnessed byBryan Last name of sampler or witnessed byStewart
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Padaro Concrtete Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number386
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected18941
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedDischarge from concrete truck into wheelbarrow. Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-04-16-78
DIME Test ID: 2026-04-16-78-4
Testing Lab: CT D05 - Carpinteria Field Laboratory
Test Method: ASTM C78-18: Standard Test Method for Flexural Strength of Concrete (Using Simple Beam with Third-Point Loading)
Test Release Date: 2026-06-11

Test Results


Number of specimens: 2
Unit system used?: US Units
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Is a beam dimensional correction factor used?: Yes
Input Type: Measured
Tester's full name: Jesse Gomez
Date of test: 04/24/2026
Identification number: 0
Width of specimen: 6.0 inch
Width of specimen 2: 6.0 inch
Depth of specimen: 6.1 inch
Depth of specimen 2: 6.1 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Maximum load applied: 7460 lb
Maximum load applied 2: 6990 lb
Correction Factor: 1
Correction Factor 2: 1
Curing history and apparent moisture condition of the specimen: Water Bath
If specimen was capped, ground or if leather shims were used: Leather shims
Defects in specimen: 0
Age of specimen: 7 days
Age of specimen in hours: 12 hours
Modulus of rupture: 615 psi
Modulus of rupture 2: 580 psi
Modulus of rupture average: 600 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/11/2026