Summary for Test 2026-05-15-47-2

Test performed: ASTM D412-16r21

Project Information

Project IdentifiersProject ID: 1001473
DEA: 044X1404
EFIS: 0426000005
DIST-CO-RTE-PM04-SF-280-
Award DateNot set
Closeout DateNot set
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 08/06/2025)

Sample Information

Sample Taken Date05/15/2026 Sample Unique Key47
Date that the sample was received by the laboratory/organization performing the testing05/21/2026 Sample typeQuality Assurance
A brief description of the sampleElastomeric Bearing Pad The quantity of what the sample constitutes36
From where was the sample collectedManufacturer First name of sampler or witnessed byKayla
Last name of sampler or witnessed byWallace Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameDynamic Rubber
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM1 - Elastomeric Bearing Pad Mfg. Lot Number(s)CR55-009-E
Material/Compound/Elastomer IDNA Samples Representing36
Description (size)1.15"x15"x15" Comments
Description (Number of Shims)2 Type of Bearing PadSteel
Description (Thickness of Shims)14 gage Manufacturer(s)Dynamic Rubber
Batch Number315-KMC

Test Details

DIME Sample ID: 2026-05-15-47
DIME Test ID: 2026-05-15-47-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D412-16r21: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Test Release Date: 2026-06-16

Test Results


Number of specimens tested: 3
Unit of the Ultimate Tensile Values: psi
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 06/11/2026
UTM: NA
Humidity: 0 %
Temperature: 0 f
Sample 1 Median Thickness: 0.072 in
Sample 1 Thickness all Within 0.003 inch?: Yes
Sample 1 Ultimate Tensile: 2812 psi
Sample 1 Elongation (350% Min): Pass
Sample 2 Median Thickness: 0.073 in
Sample 2 Thickness all Within 0.003 inch?: Yes
Sample 2 Ultimate Tensile: 2617 psi
Sample 2 Elongation (350% Min): Pass
Sample 3 Median Thickness: 0.067 in
Sample 3 Thickness all Within 0.003 inch?: Yes
Sample 3 Ultimate Tensile: 2912 psi
Sample 3 Elongation (350% Min): Pass
Median of the Ultimate Tensile Values: 2812 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/16/2026 ✔