Summary for Test 2024-10-23-113-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 993529
DEA: 11430514
EFIS: 1119000008
DIST-CO-RTE-PM11-SD-15-R31.3/R37.1
Award Date05/27/2022
Closeout DateNot set
Work DescriptionCRCP, FIBER OPTIC CABLE, AND HMA.
Location DescriptionSAN DIEGO COUNTY IN AND NEAR ESCONDIDO FROM 0.2 MILE SOUTH OF ROUTE 15/78 SEPARATION TO 0.5 MILE NORTH OF DEER SPRINGS ROAD OVERCROSSING
QA Service Level1 (Verified on 02/07/2022)

Sample Information

Sample Taken Date10/23/2024 Sample Unique Key113
Date that the sample was received by the laboratory/organization performing the testing06/04/2026 Sample typeProduction Start-Up
A brief description of the samplePSU The quantity of what the sample constitutes3 boxes
From where was the sample collectedSupplier First name of sampler or witnessed byUnknown
Last name of sampler or witnessed byUnknown Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameMartin Marietta Lake Elsinore
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number53417105
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder SupplierValero
RAP content (%)0 WMA AdditivesNo
Antistrip type

Test Details

DIME Sample ID: 2024-10-23-113
DIME Test ID: 2024-10-23-113-1
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-06-30

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Mohammad Abbassi
Date of test: 06/11/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 3951.0 g
Mass of the specimen and specimen basket assembly prior to ignition: 6019.5 g
Mass of HMA Sample prior to ignition: 2068.5 g
Mass Loss: 119.5 g
Mass of aggregate remaining after ignition: 1949.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.06 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.72 %
General comments (publicly viewable) (Max 1000 characters): oven 2, range= 4.7% - 5.5% TWM, does not comply.

Test was verified on 6/30/2026 ✔