Summary for Test 2026-06-02-57-2

Test performed: AASHTO T240-23

Project Information

Project IdentifiersProject ID: 1000785
DEA: 081J3204
EFIS: 0818000017
COOP: NONE
DIST-CO-RTE-PM08-RIV-74-17.8
Award Date05/29/2025
Closeout DateNot set
Work DescriptionBUILDING WORK, WROUGHT IRON FENCE, HOT MIX ASPHALT, & AGGREGATE BASE.
Location DescriptionRIVERSIDE COUNTY NEAR LAKE ELSINORE AT LAKE ELSINORE MAINTENANCE STATION AT 18745 CONARD AVENUE
QA Service Level1 (Verified on 01/13/2025)

Sample Information

Sample Taken Date06/02/2026 Sample Unique Key57
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/03/2026
Sample typeVerification A brief description of the sampleAsphalt Binder Sample
The quantity of what the sample constitutes1can From where was the sample collectedSource
First name of sampler or witnessed byDylan Last name of sampler or witnessed byNault
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAll American Asphalt Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-10
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2026-06-02-57
DIME Test ID: 2026-06-02-57-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2026-07-07

Test Results


Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Angelito Villegas
Date of test: 06/05/2026
Any material loss from containers during heating process/testing?: no data
Mass of container #1 before test (m1i): 203.337 grams
Mass of container #2 before test (m2i): 207.039 grams
Mass of container #1 after test (m1f): 203.235 grams
Mass of container #2 after test (m2f): 206.937 grams
Mass of empty container #1: 168.206 grams
Mass of empty container #2: 171.920 grams
Mass correction factor: 0.006
Average mass change: -0.284 percent
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/7/2026