Summary for Test 2026-06-03-72-1

Test performed: ASTM C39-21

Project Information

Project IdentifiersProject ID: 1001176
DEA: 042Q5204
EFIS: 0419000021
DIST-CO-RTE-PM04-SOL-29-0.0/6.0
Award Date07/14/2025
Closeout DateNot set
Work DescriptionHMA PVMT, MOD DRAINAGE, SIGNALS, SIDEWALKS, CURB RAMPS AND LANDSCAPE.
Location DescriptionSOLANO COUNTY IN VALLEJO FROM 0.2 MILE NORTH OF ROUTE 80/ 29 SEPARATION TO NAPA COUNTY LINE
QA Service Level1 (Verified on 08/14/2025)

Sample Information

Sample Taken Date06/03/2026 Sample Unique Key72
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/09/2026
Sample typeQuality Assurance A brief description of the sampleBasement Repair, sidewalk/ Ceiling pour
The quantity of what the sample constitutesSidewalk From where was the sample collectedJob Site
First name of sampler or witnessed byM.B. Last name of sampler or witnessed byKim
Title of samplerASR Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan - Pleasanton Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberD20115E1
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedTBD
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedTruck Chute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-06-03-72
DIME Test ID: 2026-06-03-72-1
Testing Lab: CT HQ - Vallejo Field Laboratory
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2026-06-10

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Daniel Arreola
Date of test: 06/10/2026
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1: 9 lb
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 42960 lb
Maximum load on cylinder 2: 40900 lb
Maximum load on cylinder 3: 45310 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 6
Type of fracture pattern of cylinder 3: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 0 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 3420.0 psi
Compressive strength of cylinder 2: 3250.0 psi
Compressive strength of cylinder 3: 3600 psi
Compressive strength (to nearest 10 psi): 3420 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters): 6sk - MixID: D20115E1

Test was verified on 6/10/2026