Summary for Test 2026-05-15-71-2
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 1000513 DEA: 020J8504 EFIS: 0219000168 |
|---|---|
| DIST-CO-RTE-PM | 02-SIS-89-21/R34.622 |
| Award Date | 08/05/2025 |
| Closeout Date | Not set |
| Work Description | MCCLOUD CAPM - PAVEMENT REHABILITATION |
| Location Description | IN SISKIYOU COUNTY AT AND NEAR MCCLOUD FROM 0.1 MILE SOUTH OF MUD CREEK BRIDGE TO ROUTE 5 |
| QA Service Level | 1 (Verified on 08/12/2024) |
Sample Information
| Sample Taken Date | 05/15/2026 | Sample Unique Key | 71 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/15/2026 |
| Sample type | Production Start-Up | A brief description of the sample | 2 bags of Fine RAP (3/8-inch) |
| The quantity of what the sample constitutes | Production Start-Up Evaluation | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | G | Last name of sampler or witnessed by | Giuntoli |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | D80196 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Tullis — Northstate Asphalt (Redding, CA) | Transportation Laboratory (TL) Number | 877620 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | 3952019 |
Material Information
| Material Type | Reclaimed Asphalt Pavement | RAP Source | Northstate Asphalt |
|---|---|---|---|
| Aggregate Size | 3/8-inch | Aggregate Source | |
| RAP Stockpile | Stockpile Size (tons) | ||
| Reclaimed Asphalt Pavement Mix Number |
Test Details
DIME Sample ID: 2026-05-15-71
DIME Test ID: 2026-05-15-71-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2026-06-09
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 05/21/2026
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7330.6 grams
Mass of oven-dry sample in air for Sample 1: 1672.7 grams
Mass of container filled with the sample and water for Sample 1: 8335.5 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.505
Theoretical maximum density at 25°C (77°F): 2497.7 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Gmmr=2.505
Test was verified on 6/9/2026 ✔