Summary for Test 2026-05-17-22-1

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 1001683
DEA: 040AA194
EFIS: 0419000450
DIST-CO-RTE-PM04-CC-4-R29.0/R44.4
Award Date01/09/2026
Closeout DateNot set
Work DescriptionCOLD PLANE AC PVMT, RHMA-G & HMA OVERLAY, REPLACE AC SURF, & MGS.
Location DescriptionCONTRA COSTA COUNTY IN ANTIOCH AND AT BYRON FROM HILLCREST AVENUE OVERCROSSING TO BYRON HIGHWAY
QA Service Level1 (Verified on 10/06/2025)

Sample Information

Sample Taken Date05/17/2026 Sample Unique Key22
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/02/2026
Sample typeQuality Assurance A brief description of the sample1/2" WMA-RAP 25
The quantity of what the sample constitutes2 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byAnthony Last name of sampler or witnessed byValdez
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert Materials Vernalis Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)SMARA 91-39-0041
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedConveyor Belt
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number1
Sublot number7 Aggregate Mix Number

Test Details

DIME Sample ID: 2026-05-17-22
DIME Test ID: 2026-05-17-22-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2026-06-08

Test Results


Number of tests: 1
Input Type: Measured
Tester's full name: Henry Concepcion
Date of test: 06/02/2026
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 52
Sand reading (test 1): 43
Sand equivalent (test 1): 83
Sand equivalent before temperature correction: 83
Sand equivalent after temperature correction: 83
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/8/2026