Summary for Test 2026-05-20-3-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 1002077 DEA: 033H5904 EFIS: 0318000017 |
|---|---|
| DIST-CO-RTE-PM | 03-PLA-80-R26.3/R55.2 |
| Award Date | 01/08/2026 |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 04/07/2026) |
Sample Information
| Sample Taken Date | 05/20/2026 | Sample Unique Key | 3 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 05/26/2026 |
| Sample type | Quality Assurance | A brief description of the sample | #7 x 4' diameter welded hoops |
| The quantity of what the sample constitutes | 135 Hoops | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Jacob | Last name of sampler or witnessed by | Garcia |
| Title of sampler | Quality Assurance Inspector | Telephone number of sampler | 7606866753 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | TNT Rebar | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L169-067-26 | Structure unique identifier | |
| Structure name | Bid Item | 3951703 |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 1202076697 |
| Hoop Manufacturer Lot Number(s) | Lot 1 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #7 |
| Diameter of Hoop | 4'-0" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Nucor |
| Welding Company | TNT Rebar | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2026-05-20-3
DIME Test ID: 2026-05-20-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2026-06-09
Test Results
Number of Samples: 4
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 06/08/2026
UTM: NA
Temperature: 0 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 1 | 7 | 0.60 | 50960 | 84933 | NA | Atlas |
| 2 | 2 | 1 | 7 | 0.60 | 51080 | 85133 | NA | Atlas |
| 3 | 3 | 1 | 7 | 0.60 | 51150 | 85250 | NA | Atlas |
| 4 | 4 | 1 | 7 | 0.60 | 51250 | 85417 | NA | Atlas |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/9/2026 ✔