Summary for Test 2026-06-03-35-1
Test performed: CTM 217-June 2011Project Information
| Project Identifiers | Project ID: 1000510 DEA: 060W79U4 EFIS: 0622000189 |
|---|---|
| DIST-CO-RTE-PM | 06-KER,TUL-99-56.4/57.6,0.0/13.5 |
| Award Date | 04/10/2025 |
| Closeout Date | Not set |
| Work Description | RDWY EXC, HMA, AGGREGATE BASE, CRCP, SIGN STR, AND STR EXC. |
| Location Description | KERN AND TULARE COUNTIES IN AND NEAR DELANO FROM 0.2 MILE SOUTH OF CECIL AVENUE OVERCROSSING TO 0.7 MILE NORTH OF AVENUE 100 OVERCROSSING |
| QA Service Level | 1 (Verified on 08/26/2024) |
Sample Information
| Sample Taken Date | 06/03/2026 | Sample Unique Key | 35 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/04/2026 |
| Sample type | Acceptance | A brief description of the sample | Class 2 Aggregate Base |
| The quantity of what the sample constitutes | Class 2 AB | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | QC | Last name of sampler or witnessed by | QC |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Onsite Plant | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | 3906192 |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | onsite plant- SPCI |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Windrow in the field. | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2026-06-03-35
DIME Test ID: 2026-06-03-35-1
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2026-06-04
Test Results
Number of tests: 3
Input Type: Measured
Tester's full name: Barrett Felder
Date of test: 06/04/2026
Temperature correction: 0
Temperature of solution: 75
Clay reading (test 1): 9.9
Sand reading (test 1): 3.4
Clay reading (test 2): 10
Sand reading (test 2): 3.3
Clay reading (test 3): 9.6
Sand reading (test 3): 3.3
Sand equivalent (test 1): 35
Sand equivalent (test 2): 33
Sand equivalent (test 3): 35
Sand equivalent before temperature correction: 35
Sand equivalent after temperature correction: 35
General comments (publicly viewable) (Max 1000 characters):
Test File Attachments
| File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
|---|---|---|---|---|---|
| 06-0W79U4_37046_260603_Cl2AB | 102.75 KB | 06/04/2026 | 2026-06-03-35-1 | Info |
Test was verified on 6/4/2026 ✔