Summary for Test 2026-05-12-52-1
Test performed: AASHTO T30-25Project Information
| Project Identifiers | Project ID: 1001723 DEA: 050N7064 EFIS: 0524000077 |
|---|---|
| DIST-CO-RTE-PM | 05-SB-101-10.9/12.3 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | SB 101 - Segment 4E North - Cabrillo |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 11/03/2025) |
Sample Information
| Sample Taken Date | 05/12/2026 | Sample Unique Key | 52 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/12/2026 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4 HMA SP R25 |
| The quantity of what the sample constitutes | 0-750 Tons | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Jesse | Last name of sampler or witnessed by | Gomez |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Granite Santa Paula | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0046 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | deposited pile @ plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | 1 | |
| Sublot number | 5 | Aggregate Mix Number | 14851 |
Test Details
DIME Sample ID: 2026-05-12-52
DIME Test ID: 2026-05-12-52-1
Testing Lab: CT D05 - Carpinteria Field Laboratory
Test Method: AASHTO T30-25: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2026-06-04
Test Results
Individual or cumulative mass retained on each sieve?: Cumulative
Has the fine aggregate sample been reduced?: No
Is an aggregate correction factor used?: Yes
Was the aggregate obtained using ASTM D8159?: No
Input Type: Measured
Tester's full name: Bryan Stewart
Date of test: 05/12/2026
Total mass of material in the sample: 2099.2 grams
Aggregate correction factor for the 2 in. sieve (% passing): 0.0 %
Aggregate correction factor for the 1 1/2 in. sieve (% passing): 0.0 %
Aggregate correction factor for the 1 in. sieve (% passing): 0.0 %
Aggregate correction factor for the 3/4 in. sieve (% passing): -0.6 %
Aggregate correction factor for the 1/2 in. sieve (% passing): -0.5 %
Aggregate correction factor for the 3/8 in. sieve (% passing): -2.2 %
Aggregate correction factor for the #4 sieve (% passing): -1.0 %
Aggregate correction factor for the #8 sieve (% passing): -0.7 %
Aggregate correction factor for the #16 sieve (% passing): -0.8 %
Aggregate correction factor for the #30 sieve (% passing): -1.1 %
Aggregate correction factor for the #50 sieve (% passing): -1.1 %
Aggregate correction factor for the #100 sieve (% passing): -0.8 %
Aggregate correction factor for the #200 sieve (% passing): -0.5 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/4/2026 ✔
