Summary for Test 2026-04-30-5-1
Test performed: ASTM A970-18Project Information
| Project Identifiers | Project ID: 1001645 DEA: 051R1004 EFIS: 0523000125 |
|---|---|
| DIST-CO-RTE-PM | 05-SLO, -1-32.6 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | BRIDGE REPLACEMENT, HMA, AND RSP PROTECTION. |
| Location Description | SAN LUIS OBISPO COUNTY NEAR MORRO BAY AT TORO CREEK BRIDGE |
| QA Service Level | 1 (Verified on 11/03/2025) |
Sample Information
| Sample Taken Date | 04/30/2026 | Sample Unique Key | 5 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 05/05/2026 | Sample type | Quality Assurance |
| A brief description of the sample | #10 HRC 150 T-heads | The quantity of what the sample constitutes | 35163 lbs |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | N/A |
| Last name of sampler or witnessed by | N/A | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Pacific Steel | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 3500043899 | Head Manufacturer Lot Number(s) | C258173 |
| Rebar Size | #10 | Headed Bar Model Name | HRC T150 |
| Size of Head | Full Size - 9x | Head Connection Type | |
| Head Shape | Circular | Rebar Manufacturer | Nucor |
| Head Manufacturer | Wilton | Head Fabricator | HRC |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | 9FW-17-04 |
Test Details
DIME Sample ID: 2026-04-30-5
DIME Test ID: 2026-04-30-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2026-06-02
Test Results
Number of Headed Bar Samples: 4
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 06/02/2026
UTM: NA
Temperature: 0 f
| Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|
| 1 | 1 | 1.27 | 119330 | 94000 | Ok Necking | Kleinfelder |
| 2 | 1 | 1.27 | 118880 | 93500 | Ok Necking | Kleinfelder |
| 3 | 1 | 1.27 | 116430 | 91500 | Ok Necking | Kleinfelder |
| 4 | 1 | 1.27 | 118070 | 93000 | Ok Necking | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/2/2026 ✔