Summary for Test 2026-05-22-2-1
Test performed: ASTM A970-18Project Information
| Project Identifiers | Project ID: 1001361 DEA: 120M9704 EFIS: 1213000099 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-57-11.5/12.5 |
| Award Date | 09/25/2025 |
| Closeout Date | Not set |
| Work Description | CONST BRIDGES, RET WALLS, JPCP, HMA, CONC BARRIERS AND ELECT SYSTEMS. |
| Location Description | ORANGE COUNTY IN ORANGE AND ANAHEIM FROM 0.2 MILE SOUTH OF ORANGEWOOD AVENUE UNDERCROSSING TO KATELLA AVENUE UNDERCROSSING |
| QA Service Level | 1 (Verified on 07/28/2025) |
Sample Information
| Sample Taken Date | 05/22/2026 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 05/28/2026 |
| Sample type | Quality Assurance | A brief description of the sample | ASMT A706 #5 rebar w/ 120 T heads |
| The quantity of what the sample constitutes | 3122 120 T Heads | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Arthur | Last name of sampler or witnessed by | Peterson |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | HRC - Fountain Valley, CA | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 137526 | Head Manufacturer Lot Number(s) | 100013306040 |
| Rebar Size | #5 | Headed Bar Model Name | HRC 120 |
| Size of Head | Full Size - 9x | Head Connection Type | |
| Head Shape | Square | Rebar Manufacturer | Cascade Steel Rolling Mills - Oregon |
| Head Manufacturer | Nucor Cold Finish Utah | Head Fabricator | HRC Fountain Valley CA |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | 9FW-17-03 |
Test Details
DIME Sample ID: 2026-05-22-2
DIME Test ID: 2026-05-22-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2026-06-02
Test Results
Number of Headed Bar Samples: 20
Input Type: Measured
Tester's full name: Steven Paine
Date of test: 06/02/2026
UTM: NA
Temperature: 0 f
| Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|
| 1 | 1 | 0.31 | 28130 | 90500 | Ok Necking | Kleinfelder |
| 2 | 1 | 0.31 | 27470 | 88500 | Ok Necking | Kleinfelder |
| 3 | 1 | 0.31 | 29650 | 95500 | Ok Necking | Kleinfelder |
| 4 | 1 | 0.31 | 27460 | 88500 | Ok Necking | Kleinfelder |
| 5 | 6 | 0.31 | 28260 | 91000 | Ok Necking | Kleinfelder |
| 6 | 6 | 0.31 | 27810 | 89500 | Ok Necking | Kleinfelder |
| 7 | 6 | 0.31 | 28460 | 92000 | Ok Necking | Kleinfelder |
| 8 | 6 | 0.31 | 28650 | 92500 | Ok Necking | Kleinfelder |
| 9 | 11 | 0.31 | 28680 | 92500 | Ok Necking | Kleinfelder |
| 10 | 11 | 0.31 | 28680 | 92500 | Ok Necking | Kleinfelder |
| 11 | 11 | 0.31 | 28500 | 92000 | Ok Necking | Kleinfelder |
| 12 | 11 | 0.31 | 28650 | 92500 | Ok Necking | Kleinfelder |
| 13 | 16 | 0.31 | 28660 | 92500 | Ok Necking | Kleinfelder |
| 14 | 16 | 0.31 | 28600 | 92500 | Ok Necking | Kleinfelder |
| 15 | 16 | 0.31 | 28060 | 90500 | Ok Necking | Kleinfelder |
| 16 | 16 | 0.31 | 28820 | 93000 | Ok Necking | Kleinfelder |
| 17 | 21 | 0.31 | 28350 | 91500 | Ok Necking | Kleinfelder |
| 18 | 21 | 0.31 | 28100 | 90500 | Ok Necking | Kleinfelder |
| 19 | 21 | 0.31 | 28280 | 91000 | Broke at Head | Kleinfelder |
| 20 | 21 | 0.31 | 28560 | 92000 | Ok Necking | Kleinfelder |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/2/2026 ✔