Summary for Test 2026-05-05-52-7
Test performed: CTM 389-19Project Information
| Project Identifiers | Project ID: 1000513 DEA: 020J8504 EFIS: 0219000168 |
|---|---|
| DIST-CO-RTE-PM | 02-SIS-89-21/R34.622 |
| Award Date | 08/05/2025 |
| Closeout Date | Not set |
| Work Description | MCCLOUD CAPM - PAVEMENT REHABILITATION |
| Location Description | IN SISKIYOU COUNTY AT AND NEAR MCCLOUD FROM 0.1 MILE SOUTH OF MUD CREEK BRIDGE TO ROUTE 5 |
| QA Service Level | 1 (Verified on 08/12/2024) |
Sample Information
| Sample Taken Date | 05/05/2026 | Sample Unique Key | 52 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/05/2026 |
| Sample type | Production Start-Up | A brief description of the sample | 16 boxes of Unverified Lime Treated 1/2-inch Type A (eq. PG 64-16) |
| The quantity of what the sample constitutes | Production Start-Up Evaluation | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Delgado |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | D80189 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Tullis — Northstate Asphalt (Redding, CA) | Transportation Laboratory (TL) Number | 875618 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 01 | HMA Mix Number | 2603P01 |
| Binder content (%) | 5.2 | Virgin binder PG | PG 58-22 |
| Design binder PG | PG 64-16 | Binder Supplier | Albina (Klamath Falls, OR) |
| RAP content (%) | 25 | WMA Additives | No |
| Antistrip type | Lime |
Test Details
DIME Sample ID: 2026-05-05-52
DIME Test ID: 2026-05-05-52-7
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2026-06-01
Test Results
Specified number of passes at 12.7 mm: 15000
Specimen Preparation Method: PMLC
Input Type: Measured
Tester's full name: Josh Murphy
Date of test: 05/14/2026
Test Temperature: 122 F
Compaction Method: SGC Cylindrical Specimen
Air Void Content for specimen A-1: 7.3 %
Air Void Content for specimen A-2: 7.4 %
Air Void Content for specimen B-1: 7.3 %
Air Void Content for specimen B-2: 7.1 %
Stripping Inflection Point (Wheel A): >15000
Stripping Inflection Point (Wheel B): >15000
Maximum impression at 5000 passes (left wheel): 2.25 mm
Maximum impression at 5000 passes (right wheel): 2.11 mm
Average impression at 5000 passes (left/right avg): 2.18 mm
Maximum impression at 10000 passes (left wheel): 2.65 mm
Maximum impression at 10000 passes (right wheel): 2.51 mm
Average impression at 10000 passes (left/right avg): 2.58 mm
Maximum impression at 15000 passes (left wheel): 2.95 mm
Maximum impression at 15000 passes (right wheel): 2.79 mm
Average impression at 15000 passes (left/right avg): 2.87 mm
Maximum impression at 20000 passes (left wheel): no data
Maximum impression at 20000 passes (right wheel): no data
Average impression at 20000 passes (left/right avg): no data
Maximum impression at 25000 passes (left wheel): no data
Maximum impression at 25000 passes (right wheel): no data
Average impression at 25000 passes (left/right avg): no data
Raw Data: no data
General comments (publicly viewable) (Max 1000 characters): CT 360:
SA=0.3g/cm²;
CT 389:
Rut=0.1in.@N₁₅₀₀₀,
Nf>15000,
SIP>15000
Test File Attachments
| File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
|---|---|---|---|---|---|
| D80189, 02-0J8503, 875618, HWT | 919.26 KB | 06/01/2026 | 2026-05-05-52-7 | Info |
Test was verified on 6/1/2026 ✔