Summary for Test 2026-05-20-82-1

Test performed: AASHTO T308-25

Project Information

Project IdentifiersProject ID: 1000501
DEA: 081J6104
EFIS: 0818000102
DIST-CO-RTE-PM08-RIV-215-40.5/42.7
Award Date11/05/2024
Closeout DateNot set
Work DescriptionINDIVIDUAL SLAB REPLACEMENT (RSC), RHMA, AND REPLACE BASE.
Location DescriptionRIVERSIDE COUNTY IN RIVERSIDE FROM 0.8 MILE SOUTH OF ROUTE 60/91 SEPARATION TO 0.4 MILE SOUTH OF MARTIN LUTHER KING BOULEVARD UNDERCROSSING
QA Service Level1 (Verified on 09/02/2024)

Sample Information

Sample Taken Date05/20/2026 Sample Unique Key82
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/20/2026
Sample typeAcceptance A brief description of the sample3/4 RHMA-G
The quantity of what the sample constitutes2 BOXES, 857.93 TONS From where was the sample collectedSupplier
First name of sampler or witnessed byFrancisco Last name of sampler or witnessed byRUVALCABA
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRJ Noble Orange Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number1
Sublot number7 HMA Mix Number49R003ARSPWEO
Binder content (%)7.5 Virgin binder PG PG 64-16
Design binder PG PG 64-16 Binder SupplierWorld Oil
RAP content (%)0 WMA AdditivesNo
Antistrip type0.25% INGEVITY EVOTHERM

Test Details

DIME Sample ID: 2026-05-20-82
DIME Test ID: 2026-05-20-82-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-06-05

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Elias Hamel
Date of test: 05/26/2026
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2174.0 g
Mass Loss: 176.6 g
Correction Factor (Percent by mass of HMA Specimen): 0.27 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.06 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.79 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/5/2026