Summary for Test 2026-05-27-33-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1001960 DEA: 081J65U4 EFIS: 0824000091 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-10-0.0/R8.2 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | HMA, RHMA, JPCP, JPCP(RSC), and individual slab replacement (RSC). |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 03/23/2026) |
Sample Information
| Sample Taken Date | 05/27/2026 | Sample Unique Key | 33 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 05/28/2026 | Sample type | Acceptance |
| A brief description of the sample | 3/4" HMA-A | The quantity of what the sample constitutes | 2 boxes |
| From where was the sample collected | Source | First name of sampler or witnessed by | Dylan |
| Last name of sampler or witnessed by | Nault | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | AAA - CORONA | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-05-27-33
DIME Test ID: 2026-05-27-33-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-06-02
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Vincent Onoh
Date of test: 06/01/2026
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2202.0 g
Mass Loss: 113.6 g
Correction Factor (Percent by mass of HMA Specimen): 0.36 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 4.66 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/2/2026 ✔