Summary for Test 2026-05-31-1-2
Test performed: AASHTO T209-25Project Information
| Project Identifiers | Project ID: 995236 DEA: 060U2904 EFIS: 0616000001 |
|---|---|
| DIST-CO-RTE-PM | 06-KER-184-1.1/8.3 |
| Award Date | 08/14/2025 |
| Closeout Date | Not set |
| Work Description | COLD PLANE & OVERLAY WITH HMA/RHMA, CONSTRUCT SIDEWALKS & CURB RAMPS. |
| Location Description | KERN COUNTY NEAR BAKERSFIELD FROM WHARTON AVENUE TO EDISON HIGHWAY |
| QA Service Level | 1 (Verified on 12/18/2024) |
Sample Information
| Sample Taken Date | 05/31/2026 | Sample Unique Key | 1 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 06/01/2026 | Sample type | Acceptance |
| A brief description of the sample | 3/4" HMA- A with 15% Rap | The quantity of what the sample constitutes | L1SL25 |
| From where was the sample collected | Source | First name of sampler or witnessed by | Alex |
| Last name of sampler or witnessed by | Escobar | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Griffith Edmonston | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | 3936550 |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 25 | HMA Mix Number | |
| Binder content (%) | 4.6 | Virgin binder PG | PG 64-16 |
| Design binder PG | PG 64-16 | Binder Supplier | |
| RAP content (%) | Not set | WMA Additives | No |
| Antistrip type | .8% Lime |
Test Details
DIME Sample ID: 2026-05-31-1
DIME Test ID: 2026-05-31-1-2
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: AASHTO T209-25: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2026-06-01
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Alex Escobar
Date of test: 06/01/2026
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7327.0 grams
Mass of oven-dry sample in air for Sample 1: 2685.2 grams
Mass of container filled with the sample and water for Sample 1: 8969.0 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.574
Theoretical maximum density at 25°C (77°F): 2567 kg/m^3
General comments (publicly viewable) (Max 1000 characters):
Test File Attachments
| File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
|---|---|---|---|---|---|
| 06-0U2904_37043_260531_L1SL25_T209 | 152.56 KB | 06/01/2026 | 2026-05-31-1-2 | Info |
Test was verified on 6/1/2026 ✔