Summary for Test 2026-05-17-20-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 1000607
DEA: 081K6904
EFIS: 0819000090
DIST-CO-RTE-PM08-RIV-74-5.7/11.8
Award Date01/09/2025
Closeout DateNot set
Work DescriptionROCK EXCAVATION, HMA (TYPE A), RHMA-G, AND CABLE NET DRAPERY SYSTEM.
Location DescriptionRIVERSIDE COUNTY IN AND NEAR LAKE ELSINORE FROM MONTE VISTA STREET TO GRAND AVENUE
QA Service Level1 (Verified on 01/13/2025)

Sample Information

Sample Taken Date05/17/2026 Sample Unique Key20
Date that the sample was received by the laboratory/organization performing the testing05/18/2026 Sample typeAcceptance
A brief description of the sampleHMA-A SP 3/4" PG58-16 The quantity of what the sample constitutes1506.35 Tons @ 12:26pm
From where was the sample collectedManufacturer First name of sampler or witnessed byGabriel
Last name of sampler or witnessed byRamirez Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameMartin Marietta — Lake Elsinore Drum Plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0098
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut at Martin Marietta Lake Elsinore Drum Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number53417105

Test Details

DIME Sample ID: 2026-05-17-20
DIME Test ID: 2026-05-17-20-1
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2026-05-29

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Measured
Tester's full name: Idris Najjar
Date of test: 05/19/2026
Cumulative Mass RetainedCumulative Percent Passing
5045.7 grams
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
262.2 grams95 %
1388.2 grams72 %
2013.7 grams60 %
2865.1 grams43 %
506 grams
156.8 grams30 %
287.9 grams19 %
365.2 grams12 %
414.8 grams8 %
442.8 grams5 %
457.6 grams4.1 %
458.3 grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/29/2026 ✔