Summary for Test 2026-05-09-4-1

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 1001245
DEA: 040AA624
EFIS: 0419000518
DIST-CO-RTE-PM04-SF-1-0.9/5.8
Award Date07/23/2025
Closeout DateNot set
Work DescriptionCOLD PLANE AC PVMT, HMA (TYPE A) AND INDIVIDUAL SLAB REPLACEMENT.
Location DescriptionTHE CITY AND COUNTY OF SAN FRANCISCO FROM HOLLOWAY AVENUE TO CALIFORNIA STREET
QA Service Level1 (Verified on 10/23/2025)

Sample Information

Sample Taken Date05/09/2026 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/11/2026
Sample typeQuality Assurance A brief description of the sample1/2"HMA w/15% RAP
The quantity of what the sample constitutes750 Tons From where was the sample collectedSource
First name of sampler or witnessed byLeo Last name of sampler or witnessed byMendoza
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGraniterock Redwood City Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-35-0012
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant Sampler
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number326122

Test Details

DIME Sample ID: 2026-05-09-4
DIME Test ID: 2026-05-09-4-1
Testing Lab: CT D04 - Pleasanton Field Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2026-05-28

Test Results


How many times will the test be run?: Once
Input Type: Measured
Tester's full name: Leo Mendoza
Date of test: 05/19/2026
Clay reading: 4.7
Sand reading: 4.1
Sand Equivalent: 88
General comments (publicly viewable) (Max 1000 characters): Lot 1 SL. 13

Test was verified on 5/28/2026