Summary for Test 2026-04-29-67-2

Test performed: ASTM C39-21

Project Information

Project IdentifiersProject ID: 1002012
DEA: 034J4304
EFIS: 0323000146
DIST-CO-RTE-PM03-UNKNOWN--
Award DateNot set
Closeout DateNot set
Work DescriptionBuilding Construction
Location DescriptionKYBURZ MAINTENANCE STATION AT 13561 HIGHWAY 50
QA Service Level1 (Verified on 03/24/2026)

Sample Information

Sample Taken Date04/29/2026 Sample Unique Key67
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/01/2026
Sample typeQuality Assurance A brief description of the sample4x8 Concrete Cylinders
The quantity of what the sample constitutes12 Cylinders From where was the sample collectedJob Site
First name of sampler or witnessed byAndrew Last name of sampler or witnessed byElias
Title of samplerASR Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSierra Tahoe Ready Mix Transportation Laboratory (TL) Number115102
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameKyburz Maintenance Station Structural Slab Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberD673A
The truck number from where the sample was collected9 The batch plant ticket number from where the sample was collected96428
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedChute Where the material sample would have been placed if not sampledStructural Slab
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2026-04-29-67
DIME Test ID: 2026-04-29-67-2
Testing Lab: CT SC - 3665 - Shingle Springs
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2026-05-28

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Treven Fulkerson
Date of test: 05/05/2026
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Apparent mass of submerged cylinder 1: 0 lb
Average diameter of cylinder 1: 4.01 in
Average diameter of cylinder 2: 4.02 in
Average diameter of cylinder 3: 4.01 in
Maximum load on cylinder 1: 29330 lb
Maximum load on cylinder 2: 28380 lb
Maximum load on cylinder 3: 26960 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 6 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.63 in^2
Cross sectional area of cylinder 2: 12.69 in^2
Cross sectional area of cylinder 3: 12.63 in^2
Compressive strength of cylinder 1: 2320.0 psi
Compressive strength of cylinder 2: 2240.0 psi
Compressive strength of cylinder 3: 2130 psi
Compressive strength (to nearest 10 psi): 2230 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters): Tested by D10 - Cherokee Lab

Test was verified on 5/28/2026