Summary for Test 2026-04-01-110-3
Test performed: ASTM D5329-20Project Information
| Project Identifiers | Project ID: 1002228 DEA: 051R7604 EFIS: 0524000115 |
|---|---|
| DIST-CO-RTE-PM | 05-SLO-229-5.5/9.2 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | RHMA-G overlay, asphalt rubber binder chip seal, & shoulder backing |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 05/01/2026) |
Sample Information
| Sample Taken Date | 04/01/2026 | Sample Unique Key | 110 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/30/2026 | Sample type | Verification |
| A brief description of the sample | PG 64-16 Rubber Blend | The quantity of what the sample constitutes | 5 Quart Cans |
| From where was the sample collected | Source | First name of sampler or witnessed by | Unknown |
| Last name of sampler or witnessed by | Unknown | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 26220 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | American Pavement Systems | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
|---|---|---|---|
| Performance Grade | PG 64-16 | Lot number | |
| Sublot number | Asphalt Rubber Binder Mix Number | 26220 |
Test Details
DIME Sample ID: 2026-04-01-110
DIME Test ID: 2026-04-01-110-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D5329-20: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2026-05-27
Test Results
Input Type: Measured
Tester's full name: Erik Svensson
Date of test: 05/27/2026
Temperature: 25 C
Ball Penetration (P1): 1 mm
Final Dial reading (F1): 51 mm
Ball Penetration (P2): 2 mm
Final Dial reading (F2): 50 mm
Ball Penetration (P3): 1 mm
Final Dial reading (F3): 50 mm
Resilience 1: 50 %
Resilience 2: 52 %
Resilience 3: 51 %
Average Resilience: 51 %
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters): RESILIENCE REBOUND
Test was verified on 5/27/2026 ✔