Summary for Test 2026-05-18-45-4

Test performed: AASHTO T30-25

Project Information

Project IdentifiersProject ID: 1001246
DEA: 041Q7214
EFIS: 0423000277
DIST-CO-RTE-PM04-CC,CC,SOL-580,680,780-Var
Award Date09/25/2025
Closeout DateNot set
Work DescriptionINSTALL FIBER OPTIC CABLE SYSTEM, RAMP METERING, AND WIDEN ROADWAY.
Location DescriptionALAMEDA, CONTRA COSTA AND SOLANO COUNTIES AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 08/13/2025)

Sample Information

Sample Taken Date05/18/2026 Sample Unique Key45
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/19/2026
Sample typeProduction Start-Up A brief description of the sample3/4 HMA + 25% RAP
The quantity of what the sample constitutes750 Tons From where was the sample collectedSource
First name of sampler or witnessed byRob Last name of sampler or witnessed byLohman
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Pleasanton Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2026-05-18-45
DIME Test ID: 2026-05-18-45-4
Testing Lab: CT D04 - Pleasanton Field Laboratory
Test Method: AASHTO T30-25: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2026-05-27

Test Results


Individual or cumulative mass retained on each sieve?: Cumulative
Has the fine aggregate sample been reduced?: No
Is an aggregate correction factor used?: Yes
Was the aggregate obtained using ASTM D8159?: No
Input Type: Measured
Tester's full name: Dennis Yeung
Date of test: 05/26/2026
Total mass of material in the sample: 1889.2 grams
Aggregate correction factor for the 2 in. sieve (% passing): 0.0 %
Aggregate correction factor for the 1 1/2 in. sieve (% passing): 0.0 %
Aggregate correction factor for the 1 in. sieve (% passing): 0.0 %
Aggregate correction factor for the 3/4 in. sieve (% passing): 0.2 %
Aggregate correction factor for the 1/2 in. sieve (% passing): 1.8 %
Aggregate correction factor for the 3/8 in. sieve (% passing): 2.0 %
Aggregate correction factor for the #4 sieve (% passing): 2.1 %
Aggregate correction factor for the #8 sieve (% passing): 2.2 %
Aggregate correction factor for the #16 sieve (% passing): 2.0 %
Aggregate correction factor for the #30 sieve (% passing): 1.6 %
Aggregate correction factor for the #50 sieve (% passing): 1.3 %
Aggregate correction factor for the #100 sieve (% passing): 0.9 %
Aggregate correction factor for the #200 sieve (% passing): 0.6 %
General comments (publicly viewable) (Max 1000 characters): PSUE Sample #2

Test was verified on 5/27/2026