Summary for Test 2018-02-28-3-1
Test performed: ASTM C39-17aProject Information
| Project Identifiers | Project ID: 211671 DEA: 07281504 EFIS: 0700000552 |
|---|---|
| DIST-CO-RTE-PM | 07-LA,VEN-101-29.3/38.2,0.0/1.2 |
| Award Date | 12/09/2016 |
| Closeout Date | 05/04/2020 |
| Work Description | CONSTRUCT STORM WATER TREATMENT SYSTEMS. |
| Location Description | LOS ANGELES AND VENTURA COUNTIES AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 01/23/2017) |
Sample Information
| Sample Taken Date | 02/28/2018 | Sample Unique Key | 3 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/05/2018 |
| Sample type | Quality Assurance | A brief description of the sample | 6x12 |
| The quantity of what the sample constitutes | 2 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | A | Last name of sampler or witnessed by | ambaye |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | 960-57A | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | NATIONAL READY MIX | Transportation Laboratory (TL) Number | 960-57A |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | AUSTIN VAULT 39 FOOTING |
| Structure name | AUSTIN VAULT 39 FOOTING | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | S63061 |
|---|---|---|---|
| The truck number from where the sample was collected | 411 | The batch plant ticket number from where the sample was collected | 760953 |
| Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | NATIONAL READY MIX |
| A detailed description of where the material sample was collected | CHUTE | Where the material sample would have been placed if not sampled | AUSTIN VAULT 39 FOOTING |
| From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2018-02-28-3
DIME Test ID: 2018-02-28-3-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2018-04-04
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 03/28/2018
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 128300 lb
Maximum load on cylinder 2: 132830 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 4538.4 psi
Compressive strength of cylinder 2: 4682.1 psi
Compressive strength (to nearest 10 psi): 4610 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/28/2018 ✔