Summary for Test 2026-04-28-57-2
Test performed: AASHTO T308-25Project Information
| Project Identifiers | Project ID: 1001350 DEA: 07356804 EFIS: 0719000031 |
|---|---|
| DIST-CO-RTE-PM | 07-VEN-33,232-26.9/41.7,R3.4/R4.1 |
| Award Date | 08/22/2025 |
| Closeout Date | Not set |
| Work Description | CONSTRUCT TREATMENT BMPS. |
| Location Description | VENTURA COUNTY AT VARIOUS LOCATIONS ON ROUTE 33 FROM 1.1 MILES NORTH OF ROSE VALLEY ROAD TO 1.0 MILE SOUTH OF POTRERO SECO ROAD AND ON ROUTE 232 FROM 0.7 MILE WEST OF ROUTE 118 TO ROUTE 118 |
| QA Service Level | 1 (Verified on 07/01/2025) |
Sample Information
| Sample Taken Date | 04/28/2026 | Sample Unique Key | 57 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/30/2026 |
| Sample type | Acceptance | A brief description of the sample | 3/4 HMA-A |
| The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Michael | Last name of sampler or witnessed by | ANGEL |
| Title of sampler | Vulcan QC | Telephone number of sampler | |
| Laboratory sample identification | 26-124 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Vulcan Materials Saticoy | Transportation Laboratory (TL) Number | 019367 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 220200 SAT VLO | |
| Binder content (%) | 0.0 | Virgin binder PG | |
| Design binder PG | Binder Supplier | ||
| RAP content (%) | Not set | WMA Additives | |
| Antistrip type |
Test Details
DIME Sample ID: 2026-04-28-57
DIME Test ID: 2026-04-28-57-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T308-25: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-05-26
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Daniel Gomez
Date of test: 05/01/2026
Test procedure used?: Method A
Mass of the specimen basket assembly: 4055.1 g
Mass of the specimen and specimen basket assembly prior to ignition: 6127.8 g
Mass of HMA Sample prior to ignition: 2072.7 g
Mass Loss: 99.3 g
Mass of aggregate remaining after ignition: 1973.4 g
Correction Factor (Percent by mass of HMA Specimen): 0.18 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.61 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/26/2026 ✔