Summary for Test 2026-05-05-51-2

Test performed: AASHTO T209-12

Project Information

Project IdentifiersProject ID: 1000513
DEA: 020J8504
EFIS: 0219000168
DIST-CO-RTE-PM02-SIS-89-21/R34.622
Award Date08/05/2025
Closeout DateNot set
Work DescriptionMCCLOUD CAPM - PAVEMENT REHABILITATION
Location DescriptionIN SISKIYOU COUNTY AT AND NEAR MCCLOUD FROM 0.1 MILE SOUTH OF MUD CREEK BRIDGE TO ROUTE 5
QA Service Level1 (Verified on 08/12/2024)

Sample Information

Sample Taken Date05/05/2026 Sample Unique Key51
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/05/2026
Sample typeProduction Start-Up A brief description of the sample2 bags of Combined RAP (1/2-inch)
The quantity of what the sample constitutesProduction Start-Up Evaluation From where was the sample collectedManufacturer
First name of sampler or witnessed byJoe Last name of sampler or witnessed byDelgado
Title of sampler Telephone number of sampler
Laboratory sample identificationD80188 Linked DIME Sample ID
The fabricator/manufacturer/facility nameTullis — Northstate Asphalt (Redding, CA) Transportation Laboratory (TL) Number875619
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceNorthstate Asphalt
Aggregate Size1/2-inch Aggregate Source
RAP Stockpile Stockpile Size (tons)
Reclaimed Asphalt Pavement Mix Number

Test Details

DIME Sample ID: 2026-05-05-51
DIME Test ID: 2026-05-05-51-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2026-05-21

Test Results


Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 05/12/2026
Method Performed: no data
Mass of container filled with water: 7331.1 grams
Mass of oven-dry sample in air for Sample 1: 1608.3 grams
Mass of container filled with the sample and water for Sample 1: 8313.3 grams
Temperature of Water: 76 °F
Specific Gravity for Sample 1: 2.569
Theoretical maximum density at 25°C (77°F): 2561.5 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Gmmr=2.569

Test was verified on 5/21/2026