Summary for Test 2025-05-04-17-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 214469
DEA: 030H08U4
EFIS: 0319000029
DIST-CO-RTE-PM03-SAC-50-L0.2/R6.1
Award Date06/30/2020
Closeout DateNot set
Work DescriptionSac 50 Design Build PLEASE NOTE THAT DESIGN BUILDER MUST PERFORM QUALITY VALIDATION TESTING IN ACCORDANCE WITH THE MATERIAL CONTROL SCHEDULE (MCS) FOR ITEMS SUCH AS STRANDS, HS BOLTS, ELASTOMERIC BEARING PADS, JOINT SEALANTS, COUPLERS & WELDED HOOPS, ETC
Location DescriptionFROM 0.1 MILE EAST OF I-5 TO 0.8 MILE EAST OF WATT AVE
QA Service Level1 (Verified on 10/23/2019)

Sample Information

Sample Taken Date05/04/2025 Sample Unique Key17
Date that the sample was received by the laboratory/organization performing the testing05/06/2025 Sample typeQuality Assurance
A brief description of the sample3/4" RHMA-G The quantity of what the sample constitutes750 Tons
From where was the sample collectedSupplier First name of sampler or witnessed byChris
Last name of sampler or witnessed byEscobar Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameTeichert Perkins
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number8
Sublot number2 HMA Mix Number32140532500V
Binder content (%)0.0 Virgin binder PG
Design binder PG Binder Supplier
RAP content (%)Not set WMA Additives
Antistrip type

Test Details

DIME Sample ID: 2025-05-04-17
DIME Test ID: 2025-05-04-17-1
Testing Lab: CT D03 - Rocklin Construction Field Office
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2026-05-21

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Javier Lopez
Date of test: 05/04/2025
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1000.0 g
Mass Loss: 1.0 g
Correction Factor (Percent by mass of HMA Specimen): 1.00 %
Moisture Content: 1.00 %
Temperature Compensation Factor: 1.00 %
Test Temperature: 1000 F
Corrected Asphalt Binder Content: 7.15 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/21/2026 ✔