Summary for Test 2026-05-15-35-2

Test performed: AASHTO T240-23

Project Information

Project IdentifiersProject ID: 1000501
DEA: 081J6104
EFIS: 0818000102
DIST-CO-RTE-PM08-RIV-215-40.5/42.7
Award Date11/05/2024
Closeout DateNot set
Work DescriptionINDIVIDUAL SLAB REPLACEMENT (RSC), RHMA, AND REPLACE BASE.
Location DescriptionRIVERSIDE COUNTY IN RIVERSIDE FROM 0.8 MILE SOUTH OF ROUTE 60/91 SEPARATION TO 0.4 MILE SOUTH OF MARTIN LUTHER KING BOULEVARD UNDERCROSSING
QA Service Level1 (Verified on 09/02/2024)

Sample Information

Sample Taken Date05/15/2026 Sample Unique Key35
Date that the sample was received by the laboratory/organization performing the testing05/15/2026 Sample typeVerification
A brief description of the sampleAsphalt Binder Sample The quantity of what the sample constitutes1can
From where was the sample collectedSource First name of sampler or witnessed byDaniel
Last name of sampler or witnessed byDaniel Flures Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameRJ Noble, Orange CA
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2026-05-15-35
DIME Test ID: 2026-05-15-35-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T240-23: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2026-06-17

Test Results


Is mass change based on one or two containers?: Two
Is mass change correction factor needed?: Yes
Input Type: Measured
Tester's full name: Angelito Villegas
Date of test: 05/19/2026
Any material loss from containers during heating process/testing?: No
Mass of container #1 before test (m1i): 203.302 grams
Mass of container #2 before test (m2i): 206.919 grams
Mass of container #1 after test (m1f): 203.241 grams
Mass of container #2 after test (m2f): 206.867 grams
Mass of empty container #1: 168.204 grams
Mass of empty container #2: 171.918 grams
Mass correction factor: 0.006
Average mass change: -0.155 percent
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/17/2026 ✔