Summary for Test 2018-02-16-5-7
Test performed: ASTM C430-8Project Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 02/16/2018 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/16/2018 |
Sample type | Annual Source Testing | A brief description of the sample | Slag Cement |
The quantity of what the sample constitutes | 1 Bucket | From where was the sample collected | Source |
First name of sampler or witnessed by | Unknown | Last name of sampler or witnessed by | Unknown |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | CM185861 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Cemex | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | |
Structure name |
Material Information
Material Type | Cementitious | Brand | Cemex |
---|---|---|---|
Mill | Rizhao Shandong China | Type of Cementitious Material | Slag Cement |
Test Details
DIME Sample ID: 2018-02-16-5
DIME Test ID: 2018-02-16-5-7
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C430-8: Standard Test Method for Fineness of Hydraulic Cement by the 45-μm (No. 325) Sieve
Test Release Date: 2018-04-17
Test Results
Type of Material: Hydraulic Cement
Input Type: Measured
Tester's full name: Stephen Donnelly
Date of test: 03/23/2018
Residue from the sample retained on the No. 325 sieve (Rs): 0.0375 grams
Sieve correction factor (C): 58
Corrected residue, % (Rc): 5.9 %
Fineness of the cement as the corrected percentage passing the 45 micrometers sieve (No. 325): 94.1 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/17/2018 ✔