Summary for Test 2026-05-12-42-2

Test performed: CTM 643-April 2020

Project Information

Project IdentifiersProject ID: 1001371
DEA: 024F90U4
EFIS: 0224000157
DIST-CO-RTE-PM02-SIS-96-41.0/41.8
Award DateNot set
Closeout DateNot set
Work DescriptionHMA PAVEMENT, ELECTRICAL, LANDSCAPING AND DRAINAGE.
Location DescriptionSISKIYOU COUNTY AT AND NEAR HAPPY CAMP FROM INDIAN CREEK BRIDGE TO 0.2 MILE EAST OF DAVIS ROAD
QA Service Level1 (Verified on 07/08/2025)

Sample Information

Sample Taken Date05/12/2026 Sample Unique Key42
Date that the sample was received by the laboratory/organization performing the testing05/13/2026 Sample typeAcceptance
A brief description of the sampleNative Borrow The quantity of what the sample constitutesTrench Backfill
From where was the sample collectedManufacturer First name of sampler or witnessed byJoe
Last name of sampler or witnessed byDelgado Title of samplerConsultant
Telephone number of sampler Laboratory sample identificationD80194
Linked DIME Sample ID The fabricator/manufacturer/facility nameSt Rhodes
Transportation Laboratory (TL) Number877799 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedSample Pad
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2026-05-12-42
DIME Test ID: 2026-05-12-42-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2026-05-18

Test Results


The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Josh Murphy
Date of test: 05/18/2026
Minimum soil resistance of the lab measurement: 6950 Ohms
Soil sample temperature: 20.7 C
Soil box constant: 1
pH of soil: 6.84
Minimum soil resistance corrected to 15.5: 7853.5 Ohm-cm
Minimum soil resistivity at 15.5: 7854 Ohm-cm
General comments (publicly viewable) (Max 1000 characters): pH=6.84, p=7854.Ω∙cm

Test was verified on 5/18/2026 ✔