Summary for Test 2025-12-18-115-1

Test performed: CTM 226-July 2010

Project Information

Project IdentifiersProject ID: 209698
DEA: 072332E4
EFIS: 0700000391
COOP: 0705187
DIST-CO-RTE-PM07-LA-I-5-45.4/54
Award Date07/01/2021
Closeout DateNot set
Work DescriptionAddition of 14 miles of HOV lanes in both directions would extend existing carpool lanes on the I- 5 in San Fernando Valley to Santa Clarita Valley
Location DescriptionThe I-5 North Capacity Enhancements Project focuses on improvements to the I-5 freeway from cities of Santa Clarita and Castaic, beginning at the SR-14 interchange to Parker Rd.
QA Service Level2 (Verified on 02/03/2021)

Sample Information

Sample Taken Date12/18/2025 Sample Unique Key115
Date that the sample was received by the laboratory/organization performing the testing12/19/2025 Sample typeQuality Control
A brief description of the sampleCIP aggregates The quantity of what the sample constitutes1 per batch
From where was the sample collectedFabricator First name of sampler or witnessed byClayton
Last name of sampler or witnessed byMorris Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameNational R/M - Santa Clarita
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0046
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedbelt cut or stockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2025-12-18-115
DIME Test ID: 2025-12-18-115-1
Testing Lab: Sequoia Consultants
Test Method: CTM 226-July 2010: Method of Test for Determination of Moisture Content of Soils and Aggregates by Oven Drying
Test Release Date: 2026-05-15

Test Results


Input Type: Calculated
Tester's full name: Jorge Reyes
Date of test: 12/19/2025
Wet weight of the sample: 1000.0000000000 grams
Dry weight of the sample: 935.0000000000 grams
Weight of water in sample: 65.0000000000 grams
Percent moisture: 6.5 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/15/2026