Summary for Test 2026-05-08-40-5
Test performed: AASHTO T316-22Project Information
| Project Identifiers | Project ID: 994190 DEA: 07341604 EFIS: 0717000194 |
|---|---|
| DIST-CO-RTE-PM | 07-VEN-118-13.3/15.6 |
| Award Date | 10/25/2022 |
| Closeout Date | Not set |
| Work Description | CONSTRUCT NEW MODULAR OFFICE FACILITY. |
| Location Description | VENTURA COUNTY IN AND NEAR MOORPARK FROM 0.1 MILE EAST OF BALCOM CANYON ROAD TO 0.1 MILE WEST OF MONTAIR DRIVE |
| QA Service Level | 1 (Verified on 09/20/2022) |
Sample Information
| Sample Taken Date | 05/08/2026 | Sample Unique Key | 40 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 05/09/2026 | Sample type | Verification |
| A brief description of the sample | Asphalt Binder Sample | The quantity of what the sample constitutes | 1can |
| From where was the sample collected | Source | First name of sampler or witnessed by | Granite QC |
| Last name of sampler or witnessed by | Granite QC | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Granite Santa Paula | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 58-16 |
|---|---|---|---|
| Modified | Lot number | ||
| Sublot number | Tank number | ||
| Time of sample | HMA Supplier | ||
| Certified Asphalt Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number | ||
| HMA Type | Not set | HMA Supplier Mix ID Number | Not set |
Test Details
DIME Sample ID: 2026-05-08-40
DIME Test ID: 2026-05-08-40-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-22: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2026-06-17
Test Results
Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: Hussaya Leelakitrungruang
Date of test: 05/15/2026
Time of test: 8:39 HH:MM
Test Temperature: 135.0 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 46.4 %
Viscosity reading #1 (A) : 0.23 Pa-s
Viscosity reading #2 (B) : 0.231 Pa-s
Viscosity reading #3 (C): 0.236 Pa-s
Average viscosity: 0.232 Pa-s
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/17/2026 ✔