Summary for Test 2026-04-29-58-6

Test performed: SCAQMD 309-91-Feb93

Project Information

Project IdentifiersProject ID: 1001963
DEA: 051S3204
EFIS: 0524000214
DIST-CO-RTE-PM05-SCR--unknown
Award DateNot set
Closeout DateNot set
Work DescriptionBridge Prev Maint SBt and SCr Counties
Location DescriptionNot set
QA Service Level1 (Verified on 02/19/2026)

Sample Information

Sample Taken Date04/29/2026 Sample Unique Key58
Date that the sample was received by the laboratory/organization performing the testing05/04/2026 Sample typeQuality Control
A brief description of the sample1 gallon can / PPC 1121 RESIN The quantity of what the sample constitutes34 Totes
From where was the sample collectedSource First name of sampler or witnessed byGILBERTO
Last name of sampler or witnessed byGONZALEZ Title of samplerQuality Control Manager
Telephone number of sampler925-913-9199 Laboratory sample identification26-019
Linked DIME Sample ID The fabricator/manufacturer/facility nameKwik Bond Polymers, Benicia
Transportation Laboratory (TL) Number215KBP Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypePolyester Mfg. Lot Number(s)AZ6D00671T
Batch NumberAZ6D00671T Mix numberAZ6D00671T

Test Details

DIME Sample ID: 2026-04-29-58
DIME Test ID: 2026-04-29-58-6
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Test Release Date: 2026-05-15

Test Results


Input Type: Measured
Tester's full name: Gilberto Gonzalez
Date of test: 05/05/2026
Diameter of lid: 153.9 mm
Room Temperature: 77 f
Tare weight: no data
Initial weight: 100.065 grams
Weight at 5 minutes: 100.02 grams
Weight at 10 minutes: 99.998 grams
Weight at 15 minutes: 99.976 grams
Weight at 20 minutes: 99.953 grams
Weight at 25 minutes: 99.929 grams
Weight at 30 minutes: 99.903 grams
Final weight: 99.9 grams
Total weight loss: 0.16 grams
Calculated radius of gallon can lid in cm: 7.695 cm
Lid Factor: 53.757 m^2
Volatile emission: 8.87 grams/m^2
General comments (publicly viewable) (Max 1000 characters): Accepted supplier's result.

Test was verified on 5/15/2026 ✔